Product
JD3620 series shielding hood test platform
Live-line working shields come in various structural forms, and the pressure resistance test requires the fabrication of inner and outer electrodes with a high degree of fit according to the structure of the shield. Traditional methods use processed aluminum metal, but even with surface oxidation treatment, aluminum products will wear out over time. Once worn, aluminum powder and aluminum oxide will fall onto the shield during use. After testing, conductive powder will be present on the surface of the shield, reducing its insulation performance. The decline in insulation performance will directly threaten the personal safety of personnel working on energized lines.
Category:
Email:
Messages
Product description
Live-line working shields come in various structural forms, and the pressure resistance test requires the production of inner and outer electrodes with a high degree of fit according to the structure of the shield. Traditional methods use processed metal aluminum, but even with surface oxidation treatment, aluminum products will wear out over time. Once worn, aluminum powder and aluminum oxide will fall onto the shield during use. After testing, conductive powder will be carried on the surface of the shield, causing the insulation performance of the shield to decrease. The decrease in insulation performance will directly threaten the personal safety of personnel working on energized lines.
Our company's developed shield electrodes are made of SUS304 stainless steel combined with high-quality conductive fabric materials, solving the problem of metal powder shedding. At the same time, the conductive fabric is directly used to avoid scratches and damage that may be caused by direct contact between metal and the shield.
Main Features
- The test bench table is made of SUS304 stainless steel, which has the advantages of wear resistance and safety.
- The test bench is equipped with SUS304 stainless steel electrodes for testing insulation pads.
- Equipped with casters for easy movement.
- The test bench can be used as a testing platform for various other types of shields.
Technical Parameters
| Rated Voltage | 50kV |
| Test Bench Area | 1100×1000 (mm) |
| Insulation Pad Electrode Area | 600×600 (mm) |
| Overall Dimensions | 1100×1000×800 (mm) |

*Other types of shield electrodes can be customized*
Recommended products
SAUNDERS
If you have any suggestions or feedback on our company, please fill in the relevant information on this page and submit it. A staff member will contact you in time, or please call us directly.