NR9100 Series Fully Automatic Transformer Integrated Test System

1. The system meets the requirements for sampling and testing of distribution transformers and box-type substations below 2500kVA/10kV; 2. Human-machine interaction terminal and integrated testing device, the testing device includes intelligent measurement module, power distribution module, automatic switching line module, wiring prompt module; 3. Automatically call the intelligent measurement module, power supply module, switching device, and start the detection item by item, automatically complete the voltage, current output, parameter measurement, gear switching, and data upload of each test item


Messages

Product patent

Product description

Product Introduction

  1. The system meets the requirements for random inspection and testing of distribution transformers and box-type substations below 2500kVA/10kV;

  2. Human-machine interaction terminal and integrated testing device, the testing device includes intelligent measurement module, power distribution module, automatic switching line module, connection

  line prompt module;

  3. Automatically call the intelligent measurement module, power supply module, switching device, and start the detection item by item, automatically complete the voltage, current output, parameter measurement, gear switching, and data upload of each test item

Detection Capability
 

Serial Number

Sample Name

Category

Project Name

1

 

Transformer

 

Class B

 

Measurement of DC insulation resistance between windings and to ground

Absorption Ratio Measurement

Measurement of dielectric loss factor of insulation system capacitance (applicable to oil-immersed transformers)

Measurement of capacitance between windings and to ground

Measurement of winding resistance

Measurement of voltage ratio and verification of connection group number

Measurement of no-load loss and no-load current

Measurement of short-circuit impedance and load loss

External withstand voltage test

Induced withstand voltage test

Partial discharge measurement (applicable to dry-type transformers)

Insulating liquid test (applicable to oil-immersed transformers)

Pressure sealing test (applicable to oil-immersed transformers)

Temperature rise test

Measurement of no-load loss and no-load current at 90% and 110% rated voltage

Short-time overload capacity test (applicable to oil-immersed transformers)

Sound level determination

Pressure deformation test (applicable to oil-immersed transformers)

Measurement of zero-sequence impedance of three-phase transformer (applicable to oil-immersed transformers)

Measurement of dissolved gases in insulating liquid

2

 

American style box-type
Substation

 

Class B

 

DC insulation resistance measurement

Measurement of DC resistance unbalance rate

Measurement of voltage ratio and verification of connection group number

Measurement of no-load loss and no-load current

Measurement of short-circuit impedance and load loss

External withstand voltage test

Induced withstand voltage test

Temperature rise test

No-load current harmonic measurement

Measurement of zero-sequence impedance of three-phase transformer

3

European style box-type
Substation

Class B

Temperature rise test

SAUNDERS