  • NR1610H智能蓄电池充放电测试仪 (1).jpg

NR1600 series intelligent battery charge and discharge tester

The intelligent battery charger and discharger integrates charging, discharging, online monitoring, and activation into one device. It reduces enterprise costs, lowers the labor intensity of maintenance personnel, and provides comprehensive and scientific testing methods for battery and UPS power maintenance.


Messages

Product patent

Product description

Product Introduction
  The intelligent battery charger and discharger integrates charging, discharging, online monitoring, and activation into one device, offering multiple functionalities. It reduces enterprise costs, lowers the workload for maintenance personnel, and provides comprehensive and scientific testing methods for battery and UPS power maintenance.
 
Main Features
  ◆ Integrates charging, discharging, online monitoring, and activation, offering comprehensive functionalities in one device;
  ◆ Intelligent three-stage charging, constant current discharging, and real-time online monitoring of each battery parameter;
  ◆ Power consumption components use new PTC ceramic resistors, ensuring safety, no red-hot phenomenon, and long lifespan;
  ◆ The application of single-chip microcomputer to U-disk data transfer technology solves the problem of large-capacity data storage;
  ◆ After charging/discharging is completed, the data is transferred to a U-disk or uploaded to a computer backend for processing via the RS232 interface, automatically generating various charts to clearly show battery performance;
  ◆ Portable design, convenient for users with high mobility.
 
Technical Parameters
Item
Parameter Range
Parameter Accuracy
Total Discharge Voltage
96~270V
Resolution 10mV, Accuracy 0.1V
Total Charging Voltage Output
180~286V continuously adjustable
Resolution 10mV, Accuracy 0.1V
Charging and Discharging Single Cell Voltage
0.000V~16.00V
Resolution 1mV, Accuracy 10mV
Charging and Discharging Current
0~30A
Resolution 0.1A, Accuracy 1A
Input Load Voltage
220V
 
 
Charging and Discharging Time
0~99 hours 59 minutes
 
 
Cooling Method
Forced Air Cooling
 
 
Discharge Load
PTC Ceramic Resistor
 
 

 

SAUNDERS

If you have any suggestions or feedback on our company, please fill in the relevant information on this page and submit it. A staff member will contact you in time, or please call us directly.