Product
-
Integrated test system part
-
High voltage test series
-
Transformer test series
-
Comprehensive test series of protection and switch
-
Comprehensive measurement test
-
Test part of cable and arrester
-
Grounding and insulation test
-
Oil (gas) chemical test part
-
Comprehensive test part
-
Professional tools and accessories
-
Electric safety equipment
NR1420 series internal water cooling generator DC high voltage generator
Internal water-cooled generator DC high-voltage generator is developed for the leakage current and DC high-voltage test of internal water-cooled generator. The instrument is specially designed with various interference current compensation circuits, which can completely eliminate the influence of stray current and the polarization potential interference of the water collecting pipe during the test, and can accurately measure the leakage current of the water-cooled generator winding. For generators in power plants, DC tests can be sensitive and effective to find the end defects and gap defects of the stator windings.
◆ Large voltage feedback is used to greatly improve voltage stability. At the same time, the inverter frequency is increased, the volume and weight of the instrument and the pressure doubler are reduced, and it is more convenient to carry;
◆ Adopt intermediate frequency voltage doubler circuit, take the lead in applying the latest PWM pulse width modulation technology and high-power IGBT devices, and according to the electromagnetic compatibility theory, adopt special shielding, isolation and grounding measures, so that the instrument is high-quality, portable, and can withstand Rated voltage discharge without damage;
◆ The measurement data is displayed on a large LCD dot matrix screen;
◆ Using high-quality components from the United States and Japan and international chassis made in Germany, it has strong anti-interference ability, beautiful and practical;
◆ The voltage doubler is developed with German technology, and the intermediate frequency transformer is specially designed by relevant experts, with a small size and large capacity.
Specifications/Technical Parameters
|
60kV/80mA
|
80kV/120mA
|
90kV/200mA
|
Output voltage (kV) |
60
|
80
|
90
|
Output public current (mA) |
80
|
120
|
200
|
Output power (kW) |
4.8
|
9.6
|
18
|
Control box weight (kg) |
13
|
16
|
20
|
High pressure box weight (kg) |
16
|
20
|
26
|
Voltage measurement |
1.5%(Full scale) ±1 word
|
||
Total current measurement |
1.0%(Full scale) ±1 word
|
||
Leakage AC measurement |
±2.0%
|
||
Input power |
Three-phaseAC380V
|
SAUNDERS
WRITE A MESSAGE TO US
ADD:Building c3-09b, optical valley core center, 303 Optical Valley Avenue, Donghu New Technology Development Zone, Wuhan, China
Hotline:400-027-1230
Tel:+86-27-87690177
+86 177 6240 6910
After sales:
+86-177 0277 9566
+86-133 6724 1932
E-mail:
jd@jindian-tech.com