NR9100 series automatic transformer comprehensive test system
1. The system meets the sampling test of distribution transformers and box transformers below 2500kVA/10kV;
2. Human-computer interaction terminal and integrated integrated test device, the test device includes intelligent measurement module, power distribution module, automatic switching line module, connection
Line prompt module;
3.Automatically call the intelligent measurement module, power module, and switching device, and start testing one by one, and automatically complete the voltage, current output, parameter measurement, gear switching, and data upload of each test item.
Serial number |
Sample name |
category |
project name |
1 |
transformer |
Class B |
Winding to ground and DC insulation resistance measurement between windings |
Absorption ratio measurement |
|||
Dielectric loss factor measurement of insulation system capacitance (for oil-immersed transformers) |
|||
Winding to ground and capacitance measurement between windings |
|||
Winding resistance measurement |
|||
Voltage ratio measurement and connection group label verification |
|||
No-load loss and no-load current measurement |
|||
Short-circuit impedance and load loss measurement |
|||
Applied pressure test |
|||
Induction withstand voltage test |
|||
Partial discharge measurement (for dry-type transformers) |
|||
Insulating liquid test (for oil-immersed transformers) |
|||
Pressure sealing test (for oil-immersed transformers) |
|||
Temperature rise test |
|||
No-load loss and no-load current measurement at 90% and 110% rated voltage |
|||
Short-term overload capacity test (for oil-immersed transformers) |
|||
Sound level measurement |
|||
Pressure deformation test (for oil-immersed transformers) |
|||
Zero sequence impedance measurement of three-phase transformer (for oil-immersed transformer) |
|||
Solution gas measurement in insulating liquid |
|||
2 |
American box-type substation |
Class B |
DC insulation resistance measurement |
DC resistance unbalance rate measurement |
|||
Voltage ratio measurement and connection group label verification |
|||
No-load loss and no-load current measurement |
|||
Short-circuit impedance and load loss measurement |
|||
Applied pressure test |
|||
Induction withstand voltage test |
|||
Temperature rise test |
|||
No-load current harmonic measurement |
|||
Zero sequence impedance measurement of three-phase transformer |
|||
3 |
European-style box-type substation |
Class B |
Temperature rise test |