NR9600 series mobile distribution transformer comprehensive test system
2The system shall adopt a highly integrated integrated structure: all equipment such as test power supply, control circuit, display and measurement shall be highly integrated;
3The test vehicle is divided into human-computer interaction terminal and integrated test device. The test device shall include intelligent measurement module, power distribution module, automatic switching line module and wiring prompt module;
4Automatically call the intelligent measurement module, power supply module and switching device, start the detection item by item, and automatically complete the voltage and current output, parameter measurement, gear switching and data upload of each test item;
5The standardized module structure design shall be adopted, which is unified with the appearance structure of other intelligent measurement modules. It shall be built in the detection vehicle and shall have a direct plug-in structure design to facilitate maintenance and inspection;
6. detachable structure. For the indoor transformer and the situation that the mobile vehicle cannot enter, the test and detection device is separated from the vehicle. The device itself is supported by the on-board hydraulic rod and separated from the vehicle body. The test and detection device automatically supports the moving wheel, and electrically controls the displacement of the test device to the position of the tested transformer.
Test flow chart
Detection capability
Serial number |
Test object name |
Detection level |
Test items |
1 |
transformer |
Part B |
Measurement of DC insulation resistance between winding and ground and between windings |
Absorption ratio measurement |
|||
Winding resistance measurement |
|||
Voltage ratio measurement and connection group label verification |
|||
No load loss and no load current measurement |
|||
Short circuit impedance and load loss measurement |
|||
Induced voltage withstand test |
|||
Temperature rise test (below 630kVA) |
|||
Measurement of no-load loss and no-load current at 90% and 110% rated voltage |
|||
Zero sequence impedance measurement of three-phase transformer (below 630kVA) |
|||
Insulating oil detection |
|||
2 |
reactor |
Class C |
Winding resistance measurement |
Insulation resistance measurement of winding to ground |
|||
Insulating oil detection |
|||
3 |
Arc suppression coil |
Class C |
Insulation resistance measurement |
Winding resistance measurement |
|||
Voltage ratio measurement (with secondary winding) |
|||
Insulating oil detection |
|||
4 |
Box type substation |
Part B |
DC insulation resistance measurement |
DC Resistance Unbalance Rate Measurement |
|||
Voltage ratio measurement and connection group label verification |
|||
No load loss and no load current measurement |
|||
Short circuit impedance and load loss measurement |
|||
Induced voltage withstand test |
|||
Temperature rise test (below 630kVA) |
|||
No load current harmonic measurement |
|||
Zero sequence impedance measurement of three-phase transformer (below 630kVA) |
|||
Insulating oil detection |