NR-BX/GX (variable frequency/power frequency) series resonance test device
Used for the withstand voltage test of large-capacity, high-voltage capacitive samples such as high-voltage cables, generators, large transformers, GIS, CVT, etc.
When performing AC withstand voltage tests on large-capacity samples, the test equipment often needs to be large-capacity, which leads to the huge volume of the test equipment, which can easily reach tons, and is extremely inconvenient to carry. It is especially not suitable for on-site testing. In response to the above problems, our company has developed the NR-BX series
series frequency conversion resonance test device and NR-GX series power frequency resonance test device.
The frequency conversion resonance test device adopts the method of adjusting the power frequency. The power frequency resonance test device adopts an adjusting reactor to make the reactor and the tested capacitive sample achieve resonance, so as to obtain high voltage and large current on the tested product.
The frequency conversion host uses a dedicated SPWM digital waveform generator chip, which has small waveform distortion and stable frequency; adopts an orthogonal non-synchronous fixed carrier modulation method to ensure a good output waveform in the entire frequency range; the power part adopts advanced IPM mode
block, to ensure the stability and safety of the instrument under the minimum weight. The frequency conversion resonant booster device is composed of a frequency-regulated and voltage-regulated power supply, an excitation transformer, a reactor, and a capacitor divider. During the design process, this equipment requires that the weight of the parts that a single person can move on-site does not exceed 30kg, and the two
The weight of the parts that can be moved by the individual does not exceed 60kg, which is suitable for on-site transportation; the reactor part is cast with dry epoxy, which is beautiful and reliable, and is suitable for the requirements of AC withstand voltage test of various large-capacity samples.
◆ Simple operation: automatic test (automatic search for resonance point and automatic boost) and manual test (manual search for resonance point and manual boost) two modes to adapt to different test requirements;
◆ Can set test voltage, frequency modulation range, protection current, pressure time;
◆ Software fine frequency modulation and voltage regulation;
◆ With grounding and flashover protection functions;
◆ It can automatically track changes in the grid voltage, adjust the voltage in real time, and keep the high voltage voltage stable;
◆ Small size and light weight.
Technical Parameters
◆ Rated output voltage: 0~1000kV
◆ Output frequency: 30~300Hz
◆ Resonant voltage waveform: pure sine wave, waveform distortion rate <1.0%
◆ Continuous working time: Under flood power output, one continuous working time is 30min
◆ Quality factor: 30~90
◆ Frequency adjustment sensitivity: 0.1Hz, instability <0.5%
◆ Power supply: 220V/380V±15%, 50Hz±5%
series product configuration and scope of application/cable
Product model name | Detailed product configuration | |||
Frequency conversion source | Reactor | Excitation change | Scope of application | |
NR-BX-44/22
|
2.5kW
|
1A/22kVtwo sets
|
2.5kVA
|
10kVcable≤1kM(300m㎡)
|
NR-BX-88/22
|
4kW
|
2A/22kVtwo sets
|
4kVA
|
10kVcable≤2kM(300m㎡)
|
NR-BX-132/22
|
6kW
|
2A/22kVthree sets
|
6kVA
|
10kVcable≤3kM(300m㎡)
35kVcable≤1kM(300m㎡) |
NR-BX-176/22
|
7.5kW
|
2A/22kVfour sets
|
7.5kVA
|
10kVcable≤4kM(300m㎡)
35kVcable≤1kM(300m㎡) |
NR-BX-264/22
|
10kW
|
2A/22kVsix sets
|
10kVA
|
10kVcable≤6kM(300m㎡)
35kVcable≤2kM(300m㎡) |
NR-BX-330/22
|
15kW
|
2.5A/22kVsix sets
|
15kVA
|
10kVcable≤8kM(300m㎡)
35kVcable≤2kM(300m㎡)With 10-35kV switch and transformer |
NR-BX-640/32
|
25kW
|
2.5A/32kVeight sets
|
25kVA
|
10kVcable≤10kM(300m㎡)
35kVcable≤4kM(300m㎡) 110kVcable≤1kM(400m㎡)Compatible with 35-110kV GIS |
NR-BX-1280/32
|
50kW
|
5A/32kV eight sets
|
50kVA
|
10kVcable≤20kM(300m㎡)
35kVcable≤8kM(300m㎡) 110kVcable≤2kM(400m㎡)Compatible with 35kV-110kV GIS |
NR-BX-1950/130
|
100kW
|
3.75A/130kVfour sets
|
100kVA
|
110kV main transformer, switch, cable≤2.5kM; 220kV GIS |
NR-BX-3250/130
|
150kW
|
6.25A/130kVfour sets
|
150kVA
|
110kVcable≤5kM; 110kV-220kV main transformer, switch, GIS |
◆ Applicable scope description: Without special instructions, the 10kV cable length given in the above table is 2.0 times the cable length under the condition of 30-300Hz withstand voltage. If it is 2.5 times the withstand voltage, the cable length should be reduced by 33% accordingly. Users can choose compensation capacitors and protective ball gaps.
substation equipment
Product model name
|
Detailed product configuration | |||
Frequency conversion source | Reactor | Excitation change | Test object and scope of application | |
NR-BX-108/108
|
5kW
|
27kV/1Afour sets
|
5kVA
|
Power transformers, circuit breakers, closed bus bars and insulators with voltage levels of 35kV and below; 10kV (300 m㎡) cable 2kM; 35kV (300 m㎡) cable 0.3kM |
NR-BX-135/108
|
7.5kW
|
27kV/1.25Afour sets
|
7.5kVA
|
10kV (300 m㎡) cable 3kM; 35kV (300 m㎡) cable 0.5kM; 35kV switch, insulator, etc. |
NR-BX-216/216
|
10kW
|
54kV/1Afour sets
|
10kVA
|
110kV fully insulated main transformer, circuit breaker, busbar, GIS≤10 isolation; 35kV (300 m㎡) cable 1kM; 10kV (300 m㎡) cable 3kM |
NR-BX-270/270
|
15kW
|
54kV/1Afive sets
|
15kVA
|
110kV main transformer, switch, GIS; 35kV cable ≤1.5kM; 10kV cable ≤5kM |
NR-BX-200/400
|
10kW
|
100kV/0.5four sets
|
10kVA
|
220kV switch, GIS; 110kV main transformer, switch, GIS |
NR-BX-400/400
|
20kW
|
100kV/1Afour sets
|
20kVA
|
35-220kV main transformer, switch, GIS; 35kV cable ≤1kM; 10kV cable ≤4kM |
NR-BX-520/260
|
25kW
|
65kV/2Afour sets
|
25kVA
|
110kV fully insulated main transformer, circuit breaker, busbar, GIS≤10 partition, (300 m㎡) cable 0.8 kM; 35kV (300 m㎡) cable 3kM; 10KV (300 m㎡) cable 6kM |
NR-BX-500/500
|
20kW |
125kV/1Afour sets
|
20kVA
|
220KV and below voltage transformers, current transformers, wall bushings, pillar insulators, isolation switches, circuit breakers, insulation tools |
NR-BX-600/600
|
30kW
|
120kV/1Afour sets
|
30kVA
|
35-220kV main transformer, switch, GIS, insulator; 110kV cable ≤0.8kM; 35kV cable ≤1.1kM |
NR-BX-1600/800
|
60kW
|
200kV/2Afive sets
|
60kVA
|
35-500kV main transformer, switch, GIS, insulator; 220kV cable ≤0.5kM; 110kV cable ≤0.8kM |
generator
Product model name | Applicable generator capacity | Number of reactor configuration |
NR-GX-200/25
|
generator0.4~1.0uF(10kV/40MW)
|
200kVA/25kVOne adjustable reactor
|
NR-GX-300/50
|
generator0.27~0.33Uf(20kV/300MW)
|
300kVA/50kVOne adjustable reactor
|
NR-GX-600/50
|
generator0.113~0.45uF(20kV/600MW)
|
200kVA/50kVOne fixed reactor:400kVA/50kVOne adjustable reactor
|
NR-GX-1200/50
|
generator0.6~1.8uF(20kV/250MW)
|
200kVA/50kVOne fixed reactor:800kVA/50kVOne adjustable reactor
|
◆ Since the power frequency resonance adjustment range is relatively small, there is a certain gear break in the above table, and certain adjustments can be made according to the actual generator capacity and test voltage level.
◆ The models listed above are part of the company's conventional products. If different configurations are required, different configurations can be customized according to the parameters of the test product.
SAUNDERS
WRITE A MESSAGE TO US
ADD:Building c3-09b, optical valley core center, 303 Optical Valley Avenue, Donghu New Technology Development Zone, Wuhan, China
Hotline:400-027-1230
Tel:+86-27-87690177
+86 177 6240 6910
After sales:
+86-177 0277 9566
+86-133 6724 1932
E-mail:
jd@jindian-tech.com